XDK API  3.6.0
Documentation
Macros | Functions | Variables
Lem.c File Reference

Lem-Sensor signal sampling. More...

#include "XdkCommonInfo.h"
#include <math.h>
#include "XDK_Lem.h"
#include "BSP_BoardType.h"
#include "FreeRTOS.h"
#include "BCDS_Assert.h"
#include "task.h"
#include "timers.h"
#include "semphr.h"
#include "BCDS_MCU_Timer.h"
#include "BCDS_MCU_Timer_Handle.h"
#include "em_adc.h"
#include "em_dma.h"
#include "em_gpio.h"
#include "BSP_Adc.h"
#include "Mcu_Adc_Handle.h"
#include "Mcu_Adc.h"
#include "AdcCentral.h"
#include "AdcCentralConfig.h"
#include "BSP_LemSensor.h"
+ Include dependency graph for Lem.c:

Macros

#define ADC_BUFFER_SIZE   (ADC_CENTRAL_NO_OF_SAMPLES * NO_OF_CHANNELS_USED)
 
#define BCDS_MODULE_ID   XDK_COMMON_ID_LEMSENSOR
 
#define NO_OF_CHANNELS_USED   UINT32_C(2)
 
#define TIMER_SAMPLING_FREQ   5000UL
 

Functions

static void CalculateRunningRMS (ADC_T adc, uint32_t SamplingFreq, uint16_t *bufferPtr)
 ADC Central callback function which calculates the RMS voltage for the Differential signal from the AD5 & AD6 channels. More...
 
Retcode_T Lem_Disable (void)
 function to Deinitialize lemsensor module. More...
 
Retcode_T Lem_Enable (void)
 function to initialize the ADC, DMA , Board detect pin, Timer required for the LEM sensor sampling & Starts the sampling timer. More...
 
Retcode_T Lem_GetRmsCurrent (float *rmsCurrent)
 function to get the RMS current. More...
 
Retcode_T Lem_GetRmsVoltage (float *rmsvoltage)
 function to get the RMS voltage. More...
 
Retcode_T Lem_Setup (float currentRatedTransformationRatio)
 Initialize the required components and variables of lem sensor module. More...
 

Variables

static float CurrentRatedTransformationRatio = 0.0f
 
static volatile float RMSVoltageSumOfSquares = 0.0f
 
static uint16_t ScanData [ADC_BUFFER_SIZE]
 

Detailed Description

This module handles the LEM sensor features.

This module samples the ADC5 & ADC6 channels and calculates the RMS voltage which is updated on the window period configured by the SAMPLING_WINDOW_CYCLES

Macro Definition Documentation

#define ADC_BUFFER_SIZE   (ADC_CENTRAL_NO_OF_SAMPLES * NO_OF_CHANNELS_USED)
#define BCDS_MODULE_ID   XDK_COMMON_ID_LEMSENSOR
#define NO_OF_CHANNELS_USED   UINT32_C(2)
#define TIMER_SAMPLING_FREQ   5000UL

ADC Signal sampling frequency in Hz

Function Documentation

static void CalculateRunningRMS ( ADC_T  adc,
uint32_t  SamplingFreq,
uint16_t *  bufferPtr 
)
static
Parameters
[out]adchandle not used.
[out]SamplingFreqwhich tells the adc samples collected frequency.
[out]bufferPtrwhich is pointer to the application provided adc buffer which holds adc samples for CH5 & Ch6.

ADC central always provides 256 fixed number of adc samples per channel so the expecting the users to provide the buffer accordingly.

+ Here is the caller graph for this function:

Variable Documentation

float CurrentRatedTransformationRatio = 0.0f
static

Current rated transformation ratio for lem sensor

volatile float RMSVoltageSumOfSquares = 0.0f
static

RMS Voltage on Ch5

uint16_t ScanData[ADC_BUFFER_SIZE]
static

LEM sensor ADC user buffer for CH5